ZOVGOV High Quality Virgin Plastic Granules Resin Price PA 6 Polyamide Nylon pa6 gf 10 30 30gfhttps://forever-plastics.en.made-in-china.com/product/rJwRvlcdZpWD/China-Nylon-PA6-GF33-PA66-Granules-PA6-with-30GF-Polyamide-PA66-30-GF-PA6-Material.html25% Glass Reinforced, High Flow
Product Description | |||
25% Glass Reinforced, High Flow | |||
General | |||
Form | Resin Pellets | ||
Filler | 25 % Glass Fiber | ||
Feature Excellent Processability | |||
Physical | Nominal Value | Test Method | |
Dry: Density | 1.30 g/cm³ | ISO 1183 | |
Dry: Molding Shrinkage, Across Flow | 1.1 % | ISO 294-4 | |
Dry: Molding Shrinkage, Flow | 0.30 % | ISO 294-4 | |
Dry: Water Absorption, Saturation(23 °C) | 6.8 % | ISO 62 | |
Dry: Water Absorption, Equilibrium(50% RH;23 °C) | 1.8 % | ISO 62 | |
Mechanical | Nominal Value | Test Method | |
Dry: Tensile Modulus | 8150 MPa | ISO 527-2 | |
Dry: Tensile Stress, Break | 150 MPa | ISO 527-2 | |
Dry: Tensile Strain, Break | 3.3 % | ISO 527-2 | |
Dry: Charpy Notched Impact Strength | ISO 179 1eA | ||
-30 °C | 8.0 kJ/m² | ||
23 °C | 10 kJ/m² | ||
Dry: Charpy Unnotched Impact Strength | ISO 179 1eU | ||
-30 °C | 40 kJ/m² | ||
23 °C | 80 kJ/m² | ||
Thermal | Nominal Value | Test Method | |
Dry: Heat Deflection Temperature, Unannealed Unannealed;0.45 MPa Unannealed;1.8 MPa |
215 °C 195 °C |
ISO 75-2/B ISO 75-2/A |
|
Dry: Melting Temperature(10 °C;min) | 220 °C | ISO 11357-3 | |
Dry: CLTE, Flow | 2.0E-5 cm/cm/°C | ISO 11359-2 | |
Dry: CLTE, Transverse | 7.0E-5 cm/cm/°C | ISO 11359-2 | |
Dry: Flammability Classification(1.6 mm) | HB | IEC 60695-11-10, - 20 |
Electrical | Nominal Value | Test Method |
Dry: Volume Resistivity | 1.0E+15 ohms·cm | IEC 60093 |
Condition: Volume resistivity | 1.0E+13 ohms·cm | IEC 60093 |
Dry: Relative permittivity 100 Hz 1000000 Hz |
3.50 3.30 |
IEC 60250 |
Condition: Relative Permittivity 100 Hz 1000000 Hz |
14.0 5.00 |
IEC 60250 |
Dry: Dissipation Factor 100 Hz 1000000 Hz |
5.0E-3 0.015 |
IEC 60250 |
Condition: Dissipation factor 100 Hz 1000000 Hz |
0.30 0.12 |
IEC 60250 |
Condition: Comparative Tracking Index | 600 V | IEC 60112 |